Home Page All Audio Video Products Reference materials, engineering tables, downloads, archives, terms and conditions Product Applications Introduction to application-specific modules A collection of technical tips about our products, troubleshooting and general RDL knowledge Contact Radio Design Labs Employment opportunities Dealer Login Radio Design Labs Banner banner.php

Please submit email address to receive our newsletter

Click to view our current newsletter
2008 Trade Shows Link
PRODUCT CATEGORIES > AUDIO > SWITCHING & CONTROL >
0 ST-RX2 Audio Routing Switcher - 1x2

ST-RX2 Audio Routing Switcher - 1x2

Radio Design Labs - Audio Routing Switcher - 1x2

  • Routing of a Line‑Level Source
  • Audio Switched to One of Two Destinations
  • Silent Audio Switching
  • Balanced or Unbalanced Routing
  • Switching by Open‑Collector Logic

The ST‑RX2 has a single line‑level audio input and two line‑level audio outputs. In the absence of a control input, the NORMAL module output is fed from the audio input. When the TRIG control terminal is connected to ground, the input audio is fed to the SELECT output and the NORMAL output is switched off. When the TRIG terminal is again disconnected from ground, then the SELECT output is turned off and the NORMAL output is fed from the input. The module contains no relays or other mechanical devices. The control circuits utilize solid‑state switching to route the input signal to one of the balanced output line drivers with off attenuation better than 80 dB at all audio frequencies. Soft switching is used to eliminate clicks or pops.

The control current required at the TRIG terminal is so minimal (< 0.5 mA) that the ST‑RX2 can be controlled from nearly any source from switches to logic circuits.

The ST‑RX2 may be controlled using the RDL RC2‑ST, RT2 or RUC‑4 remote controls.

Typical Performance:

Switching Time:

Fast    |     Soft

Time required for NORMAL output to turn off:

10 us   |   5 ms

Time required for NORMAL output to turn on:

15 us   |   70 ms

Time required for SELECT output to turn off:

15 us   |   10 ms

Time required for SELECT output to turn on:

20 us   |   35 ms

Control Signal:

TRIG terminal must be externally connected to ground.

Control Current:

0.5 mA

Headroom:

> 18 dB (above +4 dBu)

THD+N:

< 0.030% (1 kHz)

CMRR:

> 45 dB (100 Hz)

Frequency Response:

15 Hz to 20 kHz (+/‑ 0.5 dB into 10 kΩ bridging input)
30 Hz to 20 kHz (+/‑ 0.5 dB into 600 Ω)

Noise:

< ‑85 dB (below +4 dBu);
‑90 dB (typical)

ON Gain:

Unity (Balanced input and output)

OFF Attenuation:

> 80 dB (Either output); > 95 dB at 1kHz

Indicators (2):

LED showing active output (left LED=NORMAL; right LED=SELECT)

Power Requirement:

GROUND‑REFERENCED, 24 to 33 Vdc @ 40 mA


Routing of  a Line-Level Source, Audio Switched to One of Two Destinations, Silent Audio Switching, Balanced Unbalanced Routing, Switching by Open-Collector Logic, The ST-RX2 has single line-level audio input two line-level audio outputs In absence of control input, NORMAL module output fed from audio input When TRIG control terminal connected to ground, input audio fed to SELECT output NORMAL output switched off When TRIG terminal again disconnected from ground, then SELECT output turned off NORMAL output fed from input module contains no relays other mechanical devices control circuits utilize solid-state switching to route input signal to one of balanced output line drivers off attenuation better than 80 dB at audio frequencies Soft switching used to eliminate clicks pops, The control current required at TRIG terminal so minimal (< 05 mA) that ST-RX2 can controlled from nearly any source from switches to logic circuits, The ST-RX2 controlled using RDL RC2-ST, RT2 RUC-4 remote controls, format converter Data/Installation


Mounting Accessories:

Mounting Kit - RU, ST and TX SeriesMB-1
Mounting Kit - RU, ST and TX Series

Kit to Mount ST, TX Series Modules on FP PanelMB-3
Kit to Mount ST, TX Series Modules on FP Panel

Snap Rail Adapter - STICK-ON SeriesMSR-1
Snap Rail Adapter - STICK-ON Series

19" Universal Rack Chassis - RU, ST and TX SeriesRC-1U
19" Universal Rack Chassis - RU, ST and TX Series

19" Rack Mount for 3 RACK-UP Series ProductsRU-RA3A
19" Rack Mount for 3 RACK-UP Series Products

STICK-ON Mounting PlateSMK-12
STICK-ON Mounting Plate

STICK-ON Series 19" Mounting Rack - 10 modulesSR-10
STICK-ON Series 19" Mounting Rack - 10 modules

STICK-ON Series 19" Mounting Rack - 12 modulesSR-12A
STICK-ON Series 19" Mounting Rack - 12 modules

STICK-ON Series Mounting Rack - 7 modulesSR-4
STICK-ON Series Mounting Rack - 7 modules

STICK-ON Series 19" Racking System - 12 modulesSTR-19A
STICK-ON Series 19" Racking System - 12 modules

STICK-ON Series 19" Racking System - 10 modulesSTR-19B
STICK-ON Series 19" Racking System - 10 modules

Single Wide Enclosure - RACK-UP MountsUC-1
Single Wide Enclosure - RACK-UP Mounts

Double Wide Enclosure - RACK-UP MountsUC-2
Double Wide Enclosure - RACK-UP Mounts

Table Top Chassis for RU, ST and TX SeriesWDG1
Table Top Chassis for RU, ST and TX Series

STICK-ON DIN Rail Adapter - 1 moduleDRA-35S
STICK-ON DIN Rail Adapter - 1 module

STICK-ON DIN Rail Adapter - 6 modulesDRA-35S6
STICK-ON DIN Rail Adapter - 6 modules


General Accessories:

STICK-ON® Series Detachable Terminal BlockDTB
STICK-ON® Series Detachable Terminal Block

Accessory Mounting SystemAMS
Accessory Mounting System


Related Products:

RC2-ST
2 Channel Remote Control for STICK-ON - Remote selection of audio or video sources

RT2
Remote Control Selector

RUC-4
ULTRASTYLE Universal Remote Control


Home
Products
Reference
Applications
Introduction
Tech Tips
Contact us
Employment
Login
Sitemap

Copyright © 2008 Radio Design Labs, Inc. RDL, Radio Design Labs, the RDL logo, STICK-ON, RACK-UP and the Rack-Up logo are registered trademarks of Radio Design Labs, Inc. Flat-Pak, RCX, SourceFlex, SupplyFlex, Sure-Lok, TX, ULTRASTYLE, and Specialists in Practical Precision Engineering are trademarks of Radio Design Labs, Inc. All other trademarks are the property of their respective owners. Typical Performance reflects product at publication time exclusive of EMC data, if any, supplied with product. Date last modified: November 20 2008